TABLE "B" - LOGIC MENU - (logic)
Logic
default Definition
Automatic
ON
tca
closing time
OFF
2-step logic
2 step
ON
3-step logic
3 step
Opening Impulse
ON
ibl open
lock
Impulse lock TCA
OFF
ibl TCA
OFF
Pre alarm
pre-alar
Hold-to-run
OFF
hold-to-run
control device
OFF
Rapid closing
fast cls
P h o t o c e l l s o n
ON
photc. open
opening
OFF
Photocell test
test phot
Direction
OFF
inv. dir
Reversal
TIMER OPEN
OFF
ti er
SCA Alarm
ON
alar sca
Fixed code
OFF
fixed code
Radio transmitter
ON
radio prog
programming
Master/Slave
OFF
aster
28
- MICHELANGELO
INSTALLATION MANUAL
ON:
Activates automatic closing
OFF: Excludes automatic closing
Note: automatic closing on TIMER release cannot be deactivated.
ON:
Enables the 2-step logic (prevails over the "3-step logic").
OFF: Disables the 2-step logic, activating the 4-step logic if the "3-step logic" is OFF.
ON:
Enables the 3-step logic (if the "2-step logic" is OFF).
OFF: Disables the 3-step logic, activating the 4-step logic if the "2-step logic" is OFF.
Barrier
closed
on closing
open
on opening
after stop
ON:
The Start impulse has no effect during the opening phase.
OFF: The Start impulse becomes effective during the opening phase.
ON:
The Start impulse has no effect during the TCA dwell period.
OFF: The Start impulse becomes effective during the TCA dwell period.
ON:
The blinker comes on about 3 seconds before the motor starts.
OFF: The blinker comes on at the same time as the motor starts.
ON:
Hold-to-run operation: the manoeuvre continues as long as the OPEN and CLOSE control keys
are kept pressed. The radio transmitter cannot be used.
OFF: Normal impulse operation.
ON:
Closes barrier after photocell disengagement, before waiting for the end of the TCA (automatic
closing time) set.
OFF: Command not entered.
ON:
In case of obscuring, this excludes photocell operation on opening. During the closing phase, it
immediately reverses the motion.
OFF: In case of obscuring, the photocells are active both on opening and on closing. When a photocell
is obscured on closing, it reverses the motion only after the photocell is disengaged.
ON:
Activates photocell check
OFF: Deactivates photocell check
ON: For right-hand fitted barrier (see Par. Right-hand fitting)
OFF: For left-hand fitted barrier
IMPORTANT: Default has no effect on the logic.
Special dip switch 1 on second-generation universal programmers.
ON:
OPEN pressed for over 3s becomes TIMER
OFF: TIMER input disabled
Signaling output on second-generation universal programmers.
ON:
The SCA contact (terminals 21-22) behaves as follows:
with barrier open and on opening: contact closed (warning light on)
with barrier closed:contact open: (warning light off)
on closing: intermittent contact (blinking)
OFF: The SCA contact closes according to the modes set by the Alarm Time parameter.
ON:
The receiver is configured for operation in fixed-code mode.
OFF: The receiver is configured for operation in rolling-code mode.
ON:
This enables transmitter storage via radio:
1 – First press the hidden key (P1) and then the normal key (T1, T2, T3 or T4) of a transmitter
already memorised in standard mode by means of the radio menu.
2 – Within 10s press the hidden key (P1) and the normal key (T1, T2, T3 or T4) of a transmitter to
be memorised.
The receiver exits the programming mode after 10s, other new transmitters can be entered before
the end of this time.
This mode does not require access to the control panel.
OFF: This disables transmitter storage via radio.
The transmitters can only be memorised using the appropriate Radio menu.
ON:
The control panel is set as Master in a centralised connection.
OFF: The control panel is set as Slave in a centralised connection.
Description
Response to the START impulse
2 steps
3 steps
opens
opens
closes
closes
stop + TCA
opens
opens
4 steps
opens
stop
closes
stop + TCA
opens