Getting Started; Electrical Connection - Ribimex Ribiland PRMCA3P Manuel D'instructions Et D'utilisation

Pompe multicellulaire & pompe surpresseur multi-cellulaire
Masquer les pouces Voir aussi pour Ribiland PRMCA3P:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5. The plug-in connector for the extension should be of the 2 pole + earth type of 10-16A/250V, in
2
accordance with CEE standards. The wire section in the cable should be equal to or greater than 1mm
. The
cable should not be lighter than cables of H05 RN-F or H07 RN-F according to model, with a wire section
equal to or greater (refer to specs table).
6. When disconnecting the power cable from the socket, always grip the plug itself and not the cable.
7. If the pump is used for emptying a pond, it should not be used when there are people in the pond.
IV. GETTING STARTED
Before any intervention on product, ensure that product is disconnected from its power source.
4.1- Unpacking
- Remove product from its packaging.
- Check that product and accessories are not damage.
4.2- Important recommendations:
Before connecting to the electrical network, you must:
- Fasten the pump securely to the ground or a suitable support.
The foot base is perforated to allow fastening bolts (not supplied) to go through.
- Ensure that the network (mains) voltage is the same as that stated on the pump specification label.
ATTENTION!
- The warranty does not cover accidents due to improper installation. This pump must be installed in
accordance with local standards and by a qualified person (we recommend you to contact an electrician).
- The fixed pipeline that will connect the pump must include a separation device having contacts with the
opening distance of at least 3 mm in all poles.
- It is recommended that the device be connected with a residual current of not more than 30 mA by means of a
residual-current-operated protective device
- The total head must not exceed the value stated on the Specifications Table.
- The cable must be at least cable [see specs table].
- To prevent vibrations, the device should be placed on an elastic support (e. g. a rubber mat).
- The installation site must be well ventilated and protected from the effects of weather.
- When being used near garden ponds and swimming pools, the device must be set up to guard against
overflowing and protected against falling in.
- Additional legal requirements must be observed
- When operating indoors you must ensure that there is a drain in the floor or a leak prevention mechanism.
- Before starting up, check the suction hose to ensure that it is sealed. Bubbles of air in the suction hose are an
indication that there may be leaks and may lead to failure of the device.

4.3- Electrical connection:

IMPORTANT: If the supply cord is damaged, it must be replaced by the manufacturer, its after-sales service
or a similarly qualified technician in order to avoid any hazard.
4.3.1- For single phase models 230V
a) Check that your mains power supply is the same as that stated on the pump rating plate.
b) Check that the supply cord is not damaged.
c) Connect the cable plug to a 10/16A wall socket fitted with an earth pin.
d) Turn power on for 1 or 2 seconds to carry out a no-load test of the pump.
Do not operate the pump for more than 2 seconds to avoid excessive over-heating. Such an occurrence would
cause permanent damage.
e) Turn power supply off and then proceed with pipes connection as set out in the following paragraphs.
f) Ensure that the electrical connection is protected against water splashing.
Page 21 / 28

Publicité

Table des Matières
loading

Table des Matières