5. The plug-in connector for the extension should be of 2-pole + earth type of 10-16A/250V, in
accordance with CEE standards. The wire section in the cable should be equal to or greater than 1mm
The cable should not be lighter than cables of H05 RN-F type.
6. When disconnecting the power cable from the socket, always grip the plug itself and not the cable.
7. These pumps can be used in swimming pools, garden ponds (eg ponds and / or garden pond,
fountains ...).
If the pump is used for emptying a swimming pool or pond, it should not be used when people or
animals are in the water.
Similarly, to avoid accidents during pump operation, it is strictly forbidden to bathe, to swim, to wash,
or to water animals near the pump.
Ensure to remove the pump before allowing people and / or animals to enter the water.
8. When the pump is immersed, handling should not be carried out using the power cable but using a
device (for ex. a rope) connected to the carrying handle.
9. Do not use power cable or float switch cable for carrying or hanging up the pump.
IV. GETTING STARTED
Before any intervention on product, ensure that product is disconnected from its power source.
4.1- Unpacking
- Remove product from its packaging.
- Check that product and accessories are not damage
4.2- Connecting the evacuation hose (Fig.2 & 3)
1. Fig.2 – Insert the washer (4) then the check valve (3) on the discharge port (1).
Screw the provided universal fitting (2) (if necessary) onto the pump outlet (1).
2. Fig.3 - Wedge the discharge hose onto the connection section corresponding to the internal
diameter of the hose.
3. Add a fixing collar (hose clamp not supplied) to complete the seal.
N.B.: For large diameter hoses and to obtain the optimum discharge output, it will be necessary to cut
the end of the universal fitting (Fig.4) so as to only keep the section suitable for the hose used.
4.3- Adjusting the floating switch
1. The float switch (14) enables the automatic start of the pump.
When the float switch reaches an angle > 45°, the pump starts up.
When the float switch lowers, then the pump will stop automatically.
2. By shortening the length of the cable between the pump and the float, it is possible to modify the
water heights that trigger starting and stopping of the pump.
3. To adjust the cut-in/cut-out height, fix the float switch cable to the float switch lock (12) provided
for this purpose.
4. Adjust the cable to the required length.
4.4- Start-up
Note: Before use, ensure discharge line is unobstructed.
Observe and respect the minimum water level and max delivery height.
The installation location should not be smaller than 800x250mm (if rectangular) or
800mm (if round).
1. The pump must be in a vertical position on a flat surface (Fig.5), ensure that it is stable during
operation.
2. Ensure that the float switch can move freely (Fig.5).
3. The suction holes must never be obstructed. It is therefore preferable that the pump should never be
2
.