Fixed Installation - Ribimex Ribiland PRMCA3P Manuel D'instructions Et D'utilisation

Pompe multicellulaire & pompe surpresseur multi-cellulaire
Masquer les pouces Voir aussi pour Ribiland PRMCA3P:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.7- Fixed installation

In the case of permanent installation, the pump must be securely attached to its support surface.
The best method is to connect the pump to the fixed piping system via a flexible hose to minimize vibration
transmission. Clamp the pump by fixing its base with suitable supports. To minimize vibration put something
under the pump base (e.g. a rubber plate). The assembly surface must be flat, dry and solid, in order to
guarantee the stability of the installation.
It is recommended to install a non-return valve to stop the flow when the unit is switched off.
Thus, the pump will not need priming, accumulate pressure and fill the hoses each time it is restarted. This
type of assembly minimizes wear and tear and saves time and energy.
In addition, it is recommended to use quick-release fasteners in the appropriate places so that the device can be
quickly separated from the fixed piping for cleaning and / or maintenance (or storing before winter).
In the event of permanent installation, the plug must be visible and easily accessible at all times.
Do not forget that water and equipment connected to the device add weight to it.
V. OPERATION
5.1- Intended use
- The water pump (whether alone or with booster tank) is designed to suck up treated water.
- The pump must be installed in a dry, ventilated location, not exposed to bad weather, heat and cold.
- The maximum suction height must not exceed [See table 1].
- When correctly installed, your pump will operate with maximum efficiency and entirely to your satisfaction.
- The water pump is designed for routine private household uses (in the house or in the garden) such as
gardening, sprinkler systems, increasing water pressure of the non-feed water distribution network, pumping
of tank water and jet washing.
- The pump must not be operated for uses not specified in this manual.
It should NOT be used in particular for:
- supplying systems and sprinkling equipment for public gardens, public parks ...
- continuous operation (for ex.: water circulation...)
- pumping corrosive liquids, easily flammable, aggressive, explosive or dangerous liquids.
- pumping seawater (salted water), waste water, water containing solids, sand or abrasive particles in
suspension, water containing corrosive substances in general.
- pumping water intended for human consumption or any other food liquid.
- pumping water / liquid having a temperature above 35°C.
NOTE:
- This pump is not designed to be used in swimming pool cleaning or other pool maintenance tasks.
- The pump must not be used in outdoor fountains, garden ponds and similar areas.
- The pump is not intended for artisanal, industrial, professional and / or commercial applications (e.g. in
construction sites, public parks, sports fields...).
5.2- Operation
Activate the power supply switch.
Additional information for BOOSTER PUMPS
- The booster pump optimizes the water supply by limiting frequent starts, and serves primarily to maintain a
constant pressure in the system.
- The pump stops automatically when the pressure in the vessel is approximately 3.5 bar.
- Slowly open the discharge valve. The pump begins to discharge, without its engine running, through the
water supply in the tank.
- When the pressure in the tank drops below about 1.5 bar, the pump starts and remains on until the pressure of
the tank reach about 3.5 bar.
Page 23 / 28