Reflector Installation And Adjustment; Use; Cleaning; Electrical Connections - Vortice THERMOLOGIKA SOLEIL SYSTEM Notice D'emploi Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
ENGLISH

Reflector installation and adjustment

NOTE: The device is suitable for outdoor installations. The device must be installed in compliance with the safety
regulations in force in the destination country and with the instructions contained in this manual.
The device must be installed on a surface or wall that is structurally suitable to support its weight (max 3 kg).
Use the bracket Kit supplied for device installation.
IMPORTANT: Correct device fixing of the cannot depend on the use of adhesives.
If installing on a wall, mount the appliance at a minimum distance from the ceiling of 30 cm and from the side
walls of 40 cm. The height from the floor can vary (min 180) (fig.1).
- Check the minimum installation dimensions.
- Position the bracket on the wall and draw the position of the holes with a pencil (fig. 3.7).
- Check vertical and horizontal hole alignments.
- Drill the fixing holes (fig. 4.8).
- Fix the wall bracket with screws and dowels, levelling it (Fig. 5.9).
- Fix the insert to support the lamp by screwing it slightly as shown in (fig. 6.10).
- Insert the lamp using the support which was previously fixed as a guide.
- Position the support roughly in the middle of the lamp, then tighten the screws.
Important: During the installation process, be sure to comply with the minimum dimensions previously indicated
in (fig. 1) and the installation directions (fig. 12,13,14,15) for wall installation (fig. 16,17,18) for ceiling installation.
If installing in a bathroom, comply with the minimum distances from showers and bathtubs, compatibly with the
provisions of the water protection standard. In addition, the device's on/off switch and adjustment controls must
not be accessible from the shower or bathtub.
In compliance with the safety constraints listed in this document, TSS is compatible with both horizontal and
vertical position installation using the respective fastening devices (fig.2).

Use

Use the switch connected during installation to switch the TSS device on/off.
In the case that the device is connected to the Power Regulator (optional accessory code 21.434), on/off and
regulation of the delivered power are carried out by means of the respective commands on the Regulator.

Cleaning

Occasionally remove dust on the satellite dish and bulb with a clean brush or compressed air so as to always
guarantee the maximum caloric efficiency of the TSS device.

Electrical connections

If TSS is installed OUTSIDE, TSS can be directly connected to the electrical grid.
For INSIDE installations :
For the different connection modes see figure A.
To connect the appliance in conformity with the current regulations it is necessary to use one of the following
modes. (fig. A)
D1: wi-fi remote controller to predict at installation (cod. 21380).
D2: plug activable through wi-fi (cod. 21379).
D3: plug activable through wi-fi with temperature sensor (cod. 21378).
1

Publicité

Table des Matières
loading

Table des Matières