Les langues disponibles

5. Withdraw the single use electrodes and correctly dispose of them.
Dispose of the single use electrodes together with any
welding waste.
6. Wait until the reaction of the Thermit
with further jobs according to the work instruction for the Thermit
procedure.

9.4.3 Preparing a new Ignition

After the ignition of a Thermit
can be replaced while the device is still on. Make sure that the used single use
electrodes have completely cooled down to reduce the danger of burns. Use
protective gloves.
Withdraw the used single use electrodes from the electrode guide. Insert new
single use electrodes.
You can ignite a new Thermit
(refer to chapter 9.4.2.).

9.4.4 Stopping the Device

To stop the device, push the ON switch.
The ON LED goes off.
9.5

After Use/Storage

After use, clean the device of dust and dirt, then put all components into the
transport case.
For long-term storage of the device make sure that the storage
location is dry (humidity not higher than 80 %) and adequately
ventilated. Storage temperatures must be between -20 °C and
+45 °C. Recharge batteries after long storage.
portion is complete. Only then continue
®
portion is completed, the single use electrodes
®
portion after approx. 30 seconds
®
welding
®
49