9.4
Operating the Device
Once the device is correctly prepared (see Chapter 9.3), you may proceed with
the operation.
9.4.1 Starting the Device
To start the device, push the ON switch. The device goes into standby and the ON
LED on the display comes on green.
Bursts of flame pose a serious burn hazard! Serious burns
may occur to the skin, hair, and eyes. To start the ignition,
insert the electrodes 40 mm deep into the Thermit
After ignition, immediately retreat to the required safe
distance. If the device is not properly inserted, the ignition
of the Thermit
®
portion will occur on the surface and result
in less time to reach the safe distance.
The reaction of the Thermit
hazard! Serious burns may occur to the skin, hair, and eyes.
When the acoustic signal sounds, immediately remove the
device from the crucible and move back at least six meters
from the crucible.
Hot single use electrodes pose a serious burn hazard! Burns
may occur to your own skin and the skin of others. Do not
touch the single use electrodes until they have cooled down.
Always handle the device carefully. The tips of the single use
electrodes may still glow after igniting the Thermit
portion poses a serious burn
®
portion.
®
portion.
®
47