LiMitationS

DP series electropumps can be used to drain rain water, infiltration water, domestic waste water and to remove water from flooded
rooms in emergency conditions. The pump can be completely or partially submersed and used to transfer clean or moderately dirty
fluids. DP - DPV series electropumps are suitable to pump dirty water containing suspended solid particles (max Ø 25 mm).
These pumps can be used both for permanent and temporary installations and in particular to empty collection basins containing
dirty or waste waters.
WARNING
The pump cannot be used for sea water and inflammable, corrosive, explosive or dangerous liquids.
WARNING
Verify that the electropump never runs without liquids.
TYPE
MAX. HEAD
SEE FIG.
DP 130/6
7 m
DP 180/7
7 m
DPV 160/6
6,5 m
The linear measures in chart are in millimetres, please refer to fig.1
• The min. priming level refers to
completely submerged outlet (See
Fig.1- ref. A)
• Sound pressure level: less than 70
dB (A)
• The pumps of this series are not
suitable for table fountains or
aquariums
CHaPter 3
inStaLLation (See FiG. 1)
DANGER - ELECTRIC SHOCK RISK
When installing, please ensure electropump is disconnected from electrical supply.
DANGER
To prevent possible injuries to people, avoid inserting hands into the mouth of the pump if this is connected to
the mains. The pumps of this series are not suitable to be used for swimming pools.
DANGER
This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
6
MIN.
MIN.
PRIMING LEVEL
DRAINAGE LEVEL
A
B
100 mm
10 mm
100 mm
10 mm
150 mm
30 mm
• If these pumps are used in continuous
mode for ponds with fish, it is
necessary to check them at regular
intervals of 6 months (if the water
contains aggressive substances)
START LEVEL
STOP LEVEL
C
D
330 mm
150 mm
330 mm
150 mm
330 mm
150 mm
• It is also advisable to check the
maximum dimension of particles
recommended for the pump and take
the necessary measures to prevent the
fish from being sucked into the pump
WEIGHT
Kg.
-
3,9
4,2
4,2