Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

BATTERY CHARGING

NOTE
Charge the batteries when the yellow or red warning light (37b or 37c) turns on, or at the end of every working cycle.
CAUTION!
Keeping the batteries charged make their life last longer.
CAUTION!
When the batteries are discharged, charge them as soon as possible, as that condition makes their life
shorter.
Check for battery charge at least once a week.
WARNING!
Battery charging produces highly explosive hydrogen gas. Charge the batteries in well-ventilated areas and
away from naked flames.
Do not smoke while charging the batteries.
While charging the battery, always keep the tank assembly open.
WARNING!
Pay careful attention when charging the batteries as there may be battery fluid leakages. The battery fluid is
corrosive. If it comes in contact with skin or eyes, rinse thoroughly with water and consult a physician.
Battery charging with battery charger installed on the machine
1.
Drive the machine on a level floor.
2.
For WET batteries only:
Open the covers (51 and 58) and check that the tanks (60 and 61) are empty, otherwise empty them through the drain
hose (10) and the tap (24).
Close the covers (51 and 58).
Carefully lift the tank assembly (71).
Check the level of electrolyte inside the batteries (72). If necessary, remove the caps (75) and top up.
When the correct level is reached, close the caps (75) and clean, if necessary, the upper surface of the batteries.
3.
Connect the battery charger cable (8) to the electrical mains (the electrical mains voltage and frequency must be compatible
with the battery charger values shown on the machine serial number plate).
NOTE
When the battery charger is connected to the electrical mains, all machine functions are automatically cut off.
If the red warning light (F, Fig. 7) on the battery charger control panel stays on, the battery charger is charging the batteries.
4.
When the green warning light (H) turns on, the battery charging is completed.
5.
When the battery charging is completed, disconnect the battery charger cable (8) from the electrical mains and wind it round
its housing (7).
6.
For WET batteries only:
Carefully lower the tank assembly (71).
Fill the tanks (60 and 61).
7.
Now the machine is ready to be used.
NOTE
For further information about the battery charger operation (I), see the relevant Manual.
9097421000(1)2008-01 A
SCRUBTEC R 361 - R 366 - R 371 - R 371 C
USER MANUAL
ENGLISH
23

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Scrubtec r 366Scrubtec r 371Scrubtec r 371 c

Table des Matières