Use; Battery Check/Setting On A New Machine - Alto SCRUBTEC R 361 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

USE

WARNING!
On some points of the machine there are some adhesive plates indicating:
DANGER
WARNING
CAUTION
CONSULTATION
While reading this Manual, the operator must pay careful attention to the symbols shown on the plates.
Do not cover these plates for any reason and immediately replace them if damaged.

BATTERY CHECK/SETTING ON A NEW MACHINE

WARNING!
The electric components of the machine can be seriously damaged if the batteries are either improperly in-
stalled or connected. The batteries must be installed by qualified personnel only. Set the function electronic
board and the integrated battery charger according to the type of batteries installed (WET or GEL) as shown
below.
Check the batteries for damage before installation.
Disconnect the battery connector and the battery charger plug.
Handle the batteries with great care.
Install the battery terminal protection caps supplied with the machine.
The machine requires one of the followings:
One 24 V battery box, 240 Ah/C5 (WET)
One 24 V battery box, 240 Ah/C5 (GEL) (optional)
No. 4 6 V batteries, 180 Ah C5 (WET)
No. 4 6 V batteries, 180 Ah C5 (GEL)
The machine can be supplied in one of the following modes:
Batteries (WET or GEL) already installed and ready to be used
1.
Open the covers (51 and 58) and check that the tanks (60 and 61) are empty, otherwise empty them through the drain hose
(10) and the tap (24).
2.
Close the covers (51 and 58).
3.
Carefully lift the tank assembly (71).
4.
Check that the batteries are connected to the machine with the connector (74).
5.
Carefully lower the tank assembly (71).
6.
Insert the ignition key (41) and turn it to "I". If the green warning light (37a) turns on, the batteries are ready to be used. If the
yellow or red warning light (37b or 37c) turns on, the batteries must be charged (see the procedure in Maintenance chapter).
Batteries (WET) installed on the machine, but without electrolyte
1.
Open the covers (51 and 58) and check that the tanks (60 and 61) are empty, otherwise empty them through the drain hose
(10) and the tap (24).
2.
Close the covers (51 and 58).
3.
Carefully lift the tank assembly (71).
4.
Remove the caps (75) of the batteries (72).
WARNING!
Pay attention when using sulphuric acid, as it is corrosive. If it comes in contact with skin or eyes, rinse thor-
oughly with water and consult a physician.
Batteries have to be filled in a well-ventilated area.
Wear protective gloves.
5.
Fill up the battery cells with sulphuric acid for batteries (density 1.27 to 1.29 kg at 25°C) as shown in the Battery Manual.
The correct quantity of sulphuric acid is shown in the Battery Manual.
6.
To avoid damaging the floor, dry with a cloth both acid and water on the top of the batteries after charging.
7.
Let the batteries rest and fill in with sulphuric acid as shown in the Battery Manual.
8.
Charge the batteries (see the procedure in Maintenance chapter).
Without batteries
1.
Buy appropriate batteries (see Technical Data paragraph).
For battery choice and installation, apply to qualified battery Retailers.
2.
Set the electronic board of the machine and of the battery charger according to the type of batteries installed (WET or GEL).
3.
Install the batteries.
4.
Charge the batteries.
9097421000(1)2008-01 A
SCRUBTEC R 361 - R 366 - R 371 - R 371 C
USER MANUAL
ENGLISH
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Scrubtec r 366Scrubtec r 371Scrubtec r 371 c

Table des Matières