Use; Battery Check/Setting On A New Machine - Alto FLOORTEC R 570 P Manuel Opérateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

USE

WARNING!
On some points of the machine there are some adhesive plates indicating:
DANGER
WARNING
CAUTION
CONSULTATION
While reading this Manual, the operator must pay careful attention to the symbols shown on the plates.
Do not cover these plates for any reason and immediately replace them if they are damaged.

BATTERY CHECK/SETTING ON A NEW MACHINE

The machine needs two 12 V lead batteries, connected according to the diagram (44).
The machine can be supplied in one of the following confi gurations:
a)
Batteries already installed and ready to be used
b)
Batteries installed on the machine but without electrolyte
c)
Without batteries
According to machine confi guration, proceed as follows.
a)
Batteries already installed and ready to be used
1.
Open the machine hood (7) and check that the batteries are connected to the dynamotor through the appropriate terminals.
2.
Close the hood (7).
3.
The machine is ready to be used.
If the batteries are discharged, charge them with an external battery charger.
b)
Batteries installed on the machine but without electrolyte
1.
Open the machine hood (7).
2.
Remove all battery caps (45).
WARNING!
Pay attention when using sulphuric acid, as it is corrosive. If it comes in contact with skin or eyes, rinse
thoroughly with water and consult a physician.
Batteries have to be fi lled in a well-ventilated area.
Wear protective gloves.
3.
Fill the battery cells with sulphuric acid for batteries (density from 1.27 to 1.29 kg at 25 °C) in accordance with the instructions
shown in the Battery Manual.
The correct quantity of sulphuric acid is shown in the Battery Manual.
4.
Let the batteries rest and fi ll in with sulphuric acid in accordance with the instructions shown in the Battery Manual.
5.
Charge the batteries with an external battery charger.
c)
Without batteries
1.
Buy appropriate batteries (see the Technical Data paragraph and the diagram (44)).
For the battery choice and installation, apply to qualifi ed battery Retailers.
2.
Install the batteries.
3.
Charge the batteries with an external battery charger.
146 2727 000(2)2007-02 A
USER MANUAL
FLOORTEC R 570 P
ENGLISH
13

Publicité

Table des Matières
loading