i
23. Technical specifications
Operating voltage power unit:
Power standby:
Power unit:
Torque:
Max. speed:
End lifting power:
Max. lifting power / initial lifting power: 25 kg
Transient operation:
Protection class:
Protection type:
Positional accuracy:
Number of switching times:
Automated solar function
adjustment range:
Ambient temperature:
Dimensions:
Permissible belt widths:
Belt lengths:
15 mm (mini belt)
23 mm (standard belt)
EC conformity has been verified
Maintenance of European low-voltage directive 2006/95/EC, EMC-directive
2004/108/EC, conforms to EN 60335-1, EN 60335-2-97, EN 55 014-1, EN 55
014-2, IEC 61558-2-6, IEC 61558-1 (Power unit).
230 V / 50 Hz
1.35 W
24 V DC / 29 W
MdN = 2.8 Nm
34 RPM
7 kg
5 minutes
III
IP20 (only for use in dry areas)
5 mm
2 (UP and DOWN)
2,000 to 20,000 Lux
0 - 40 °C
See pages 98 / 99
15 mm (mini belt)
23 mm (belt)
5.5 m for 1.0 mm belt thickness
5.5 m for 1.0 mm belt thickness
4.5 m for 1.3 mm belt thickness
EN
97