cleaning solution.
ATTENTION
When cleaning the machine, dump it, do
not allow excessive amounts of water
around
the
electrically
components of the unit. Electrical shock or
damage to the machine may result.
3
In the same manner clean the evaporator
cylinder(s) using a soft bristle brush.
4
Rinse all cleaned parts with cool clean water.
5. 3. 3 SANITIZING
Sanitizing should be performed immediately
prior to starting the machine. Do not allow the
unit to sit for extended periods of time after
sanitization.
1
Wash hands with a suitable antibacterial
soap.
2
Prepare at least two gallons of a warm (45-
60 °C 120-140 °F) sanitizing solution (100 PPM
available chlorine concentration or 1 spoon of
sodium hypoclorite diluted with 2 litres of water)
according to your local Health Codes and
manufacturer's specifications.
3
Place the parts in the sanitizing solution for
five minutes.
4
Place the sanitized parts on a clean dry
surface to air dry.
5
Wipe clean all exterior surfaces of the unit.
Do not use abrasive cleaner.
5. 3. 4 ASSEMBLY
1
Slide the drip tray into place.
2
Lubricate faucet piston, outer spiral and
outside magnetic rotor (see points A, B and C of
figure 9) only with the grease supplied by the
manufacturer or other food grade approved
lubricant.
figure 9
3
Assemble the faucet by reversing the
disassembly steps (see figure 8)
4
Fit bowl gasket around its seat.
Note: the largest brim of gasket must face
against the rear wall (see figure 10).
operated
5
Insert the magnetic outside rotor in the
evaporator taking care to accompany it to the
end (see figure 11).
6
Install the outer spiral. Slide it over the
evaporator until its hexagonal front notch
engages with the hexagonal exposed end of the
magnetic outside rotor (see figure 12).
19
figure 10
figure 11
figure 12