Stacking Icemakers - Hoshizaki IM-240DME Notice D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 7
ENGLISH
Icemaker
Drain Pipe Collar
Packing
Drain Pan
Bin Drain Hole
(P-200SD)
Storage Bin
Bin Drain Hole
(F-series)
6) Secure the icemaker with the two bolts provided. See Fig. 5.
7) Align the Storage Bin drain hole and the drain pan hole. Insert the
Packing (bin accessory) and fasten the Drain Pipe Collar (bin
accessory). See Fig. 5.
Note: On the F-series Bins, an extension drain tube kit is provided
which attaches to the icemaker Drain Pan and exits through
the pre-drilled hole in the side of the Bin.
8) Replace the icemaker panels in their correct position.

4. STACKING ICEMAKERS

WARNING
Check the icemaker models. A D-type icemaker and an X-type
icemaker will be required for stacking two icemakers. A D-type
icemaker and two X-type icemakers will be required when
stacking three icemakers. The D-type icemaker is designed for
the upper unit, and the X-type for the middle and lower units.
The D-type and X-type icemakers are provided with two different
types of Bin Control Switch. Use the Bin Control Switch of the
lower X-type icemaker only when stacking icemakers. The Bin
Control Switch must be removed from the upper (and middle)
units. Connection of the Bin Control from the lower (and middle)
to the upper unit will require additional connecting leads which
are supplied with the X-type icemaker. Misconnection or no
connection may cause serious damage to the icemaker units,
resulting in failure.
1) Prepare and position the Storage Bin as detailed in 1) and 2) in "3.
INSTALLATION".
2) Remove the icemaker panels. The Rear Panel is not required to be
removed for installation. See "1. UNPACKING".
3) Move the icemaker carefully to prevent damage to the icemaker
frame.
4) Remove the shipping tape holding the Drain Pan.
5) Attach the lower unit (X-type) on the top of the Storage Bin. See
Fig. 6.
6) Secure the lower unit with the two bolts and two plastic washers
provided. See Fig. 6.
Lower Unit
Drain Pipe Collar
Packing
Drain Pan
Extension
Extension
Drain Hole
7) Remove the shipping tape holding the Bin Control Switch on the
Drain Pan. Attach the Bin Control Switch to the frame located at
Bin Control Switch
Bolt
Fig. 5
Bolt
Washer
Fig. 6
the left bottom of the condensing unit, and secure it using the two
screws and the two washers provided. See Fig. 7.
Bin Control Switch
Drain Pan
Screw
Washer
8) [P-200SD]
Align the drain hole and the drain pan hole. Insert the Packing (bin
accessory) and fasten the Drain Pipe Collar (bin accessory) tightly,
within the recommended torque of 39.2 Nm. See Fig. 6.
9) [F-series]
Locate the extension drain tube kit. Remove the Locking Nut from
the threaded section, and push the threaded pipe through the hole
in the side of the Bin. Align the Drain Pan, and insert the Drain Pipe
Collar and Packing into the free end of tube kit and tighten. Secure
the tube kit by re-attaching the Locking Nut and tightening to the
Bin exterior.
10) Before stacking, remove the clear plastic cover on the upper or
middle unit wiring channel. Disconnect the Bin Control Switch
leads (with three-way plug). Remove the screws and the Bin
Control Switch. When stacking two or three icemakers, this switch
will not be required. Keep it after removal. See Fig. 8.
Upper Unit
Remove Bin Control Switch
11) Attach the upper or middle unit on the lower unit. See Fig. 9.
Upper Unit
Drain Pipe Collar
Packing
Drain Pan
Drain Outlet
Lower Unit
12) Secure the two units with the two bolts and the two nuts provided.
See Fig. 9.
13) Align the lower unit drain hole and the upper unit drain pan hole.
Insert the Packing (lower unit accessory) and fasten the Drain
Pipe Collar (lower unit accessory). See Fig. 9.
14) Place the Ice Chute (lower unit accessory) and secure it to the
Bracket with the two screws.
2
Handle with care
Frame
Fig. 7
Bin Control Switch
Leads
Screw
Disconnect
Fig. 8
Screw Nut
Ice Chute
Bolt
Ice Chute
Bracket
Fig. 9