6. STACKING ICEMAKERS

Check the icemaker models. A D-type icemaker and an X-type icemaker will be required for stacking two icemakers. A D-type
icemaker and two X-type icemakers will be required when stacking three icemakers. The D-type icemaker is designed for the
upper unit, and the X-type for the middle and lower units.
The D-type and X-type icemakers are provided with two different types of bin control switch. Use the bin control switch of the
lower (and middle) X-type icemakers when stacking icemakers. The bin control switch must be removed from the upper unit.
Misconnection or no connection may cause serious damage to the icemaker units, resulting in failure.
1) Prepare and position the storage bin as detailed in 1), 2) and 3) in "5.
INSTALLATION".
2) Remove the icemaker panels. The rear panel is not required to be removed for
installation. See "3. UNPACKING".
3) Attach the lower unit (X-type) on the top of the storage bin.
4) Secure the lower unit (X-type) to the storage bin at the rear, by using the
mounting brackets and bolts provided.
5) Remove the shipping tape holding the bin control switch on the drain pan.
Attach the bin control switch to the frame located at the left bottom of the
condensing unit, and secure it using the two screws and the two washers
provided.
6) Before stacking, disconnect the bin control switch leads (with three-way plug)
from the upper or middle unit. Remove the screws and the bin control switch.
When stacking two or three icemakers, the switch for the upper unit will not be
required. Keep it after removal.
7) Attach the upper or middle unit on the lower unit.
8) Secure the two units with the two bolts and the two nuts provided.
9) Place the ice chute (lower or middle unit accessory) and secure it to the
bracket with the two screws.
10) Connect the leads (with three-way plug) located in the lower unit wiring channel to the upper unit receptacle, unplugged in
the above step 6). Secure the leads using the plastic clamp provided.
Upper Unit
Lower Unit
11) Replace the icemaker panels in their correct position.
Note: If stacking three icemakers, repeat the instructions 6) - 11) for the upper unit. Remember, only ONE bin control is needed
regardless of configuration. The bin control extension leads are pre-wired with the plug and will be found coiled in the
X-type wiring channel.
NOTICE
Screw
Nut
Ice Chute
Bolt
Ice Chute
Bracket
Drain Pan
Upper Unit
Remove Bin
Control Switch
Receptacle
Plug
Upper Unit
Lower Unit
5
ENGLISH
Bin Control Switch
Handle with care
Screw
Frame
Washer
Bin Control Switch
Screw
Disconnect leads
Wiring Channel
Plastic Clamp