FIRST USE

4.1 Checking motor rotation direction
- Leave the mode with maintained pressure control.
- Check the rotation direction of the motor using the foil switches or the control point. In case of wrong rotation
direction, reverse the V and W conductors on the SD250 control box.
- Check the rotation direction with the individual control points. In case of wrong rotation direction, reverse the
conductors
and
4.2 Limit switch adjustment
Check the correct wiring of the limit switches on the control box and adjust them.
4.3 Choice of operating mode
The choice of operating mode is made using the DSW1 mini-switch located at the top right of the PCB.
The control box is supplied in pressure maintained mode.
• Maintained pressure control mode
DSW1 to OFF (no shunt 3)
- Open: press and hold the
control point.
- Closing: press and hold the
control point.
• Mixed mode (CAUTION: only allowed if
there are no crushing points, no shearing,
lifting as defined in EN 12453 (e.g. grid
with projecting parts and susceptible of
lifting a person...). Non-respect of these
recommendations results in a situation of
danger likely to lead to death or serious
injury. The choice of this mode is the full
responsibility of the installer.
DSW1 on ON + shunt 3
- Open: press the
button on SD250 or on
the control point.
- Closing: press and hold the
SD250 or on the control point.
- Stop: Press
button on SD250 or on
external STOP button during movement.
5
MAINTENANCE
PROBLEMS
When you give an impulse on the foil
switches, the motor does not react to
the command.
SIMU SAS F-70103 GRAY hereby declares that the product covered by these instructions and used as indicated in these instructions, complies with the essential
requirements of the applicable European Directives and in particular with the Machine Directive 2006/42/EC and the EMC Directive 2014/30/EU. The full text of the EU
Declaration of Conformity is available at www.simu.com. Fabrice GLORIEUX, Director General, GRAY, 06/2018.
6/6
EN
.
button or the
button or the
button on
No power supply.
A fuse is defective.
The foil switches is not connected
properly.
STOP function is activated.
10AT
10AT
10AT
SECTEUR / SUPPLY
POSSIBLE CAUSES
3
R10
Moteur
Motor
T5
T6
T7
T4
SOLUTIONS
Check the supply voltage between
terminals N and L1.
Check fuses FUS1, FUS2 and FUS3.
Check the position of the connector
on the electronic board.
Check the presence of the cable
connection between the «COMMON»
and «STOP» terminals.
OFF
ON
R8
C2
R11
R12
R9
C3
R7
TS3
BP1
BP2