3.3 Limit switch wiring and motor safety
W
W
6 x 1,5mm
2
3.4 Wiring the control points
2
moteur/motor
If you are not using the «STOP» input, leave shunt 2 in place. However, in order to control any movement, a STOP
function is mandatory: either STOP on the foil switches of the control box or STOP button. Therefore, in the case of
SD250 without foil switches, a STOP button is mandatory.
2
Refer to the motor manual to locate the upper and lower limit switches.
Locate the rotation direction and connect the upper limit switches (FCH) and
lower limit switches (FCB).
Connect the motor safety device and safety brake in series to S-M.
N1
N2
M
M
N2
M
N1
Rotary push button
C ommon
S TOP (N C)
U p (N O)
D own (NO)
Key s wi tc h
COMMON
BROWN
M
DIRECTION 1
BLACK 1
N1
DIRECTION 2
BLACK 2
N2
N2
M
N1