Fix the locking cylinder
with cylinder fixing
screw
Check for complete
functionality
Pic. 7 :
No transverse shear
stress on the bolt after
installation
EN
50
Mounting escutcheons and locking cylinders
1
Remount the escutcheons.
2
Place the lock cylinder in, and keep in mind that the cylinder's locking nose is in the middle position
(Pic. 10).
3
Fix the locking cylinder into place with the Cylinder fixing screw.
The electric multi-point lock 819 is now fully mounted.
Testing the electric multi-point lock 819
1
Test all functions of the electric multi-point lock 819.
2
Check whether the latch and auxiliary latch bolt of the lock are pushed back by the same impact edge.
3
Check whether all bolts can freely extend and retract without transverse shear stress after installation
(Pic. 7).
The electric multi-point lock 819 is fully mounted and tested for functionality.