Profile With Thermal Isolation; Reworking Profile Slugs - Assa Abloy effeff 819 Notice D'installation Et De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

A
Pic. 11 :
Rework profile slugs and
use sliding piece
Installation

Profile with thermal isolation

At tention!
Omission of reworking can result in a malfunction of the product: Reworking must take place for the
components listed below with the use of profiles with thermal isolation.
Aluminium as a stop edge can destroy components: Aluminium abrasion can destroy the lock or the
striking plate.

Reworking profile slugs

When the door is closed, the latch and control latch must slide over a level surface ("Self-locking system",
page 44). with some door frames, such as those with thermal isolation, a profile slug (Pic. 11- 1) which
has a disruptive effect on the sliding surface may be present. This profile slug must be removed in the area
of the latch and the control latch. ASSA ABLOY Sicherheitstechnik GmbH recommends using a sliding piece
(Pic. 11– 2), to create a level sliding surface..
1
Cover the existing slots or other areas of unevenness.
2
Remove the slugs. The profile slug in the latch area must be removed down to the fastening surface.
3
Check whether the latch and auxiliary latch bolt can slide unimpeded over an even surface to the
closed position when the door is closed.
 The profile slugs are smooth and the locking function is assured.
Process profile slugs
1
Rebate gap
Use sliding piece
2
Rebate gap
EN
53

Publicité

Table des Matières
loading