XX(second)
 Angle Display Format: XXX.XX(pan)/XXX.XX(tilt)
 IR Display: ☀ means the IR is turned on.

4 OSD Menu

4.1 System

<MAIN MENU>
<SYSTEM>
<DOME>
<CAMERA>
<IR>
<DISPLAY>
<TIME>
<LANGUAGE>
<RESET>
EXIT
<SYSTEM>
PROTOCOL
PELCO-D/P
COMM
DOME ID
MODULE
VERSION
MAX SPEED
<COMM SET>
<PASSWORD SET>
EXIT
CANCEL
<COMM SET>
DEVICE ID
CHECK ID
TARGET ID
BAUDE RATE
SAVE
EXIT
20
<SYSTEM>
 PROTOCOL: Displays the protocol of the dome.
 COMM: represents the communication Information; 2400 is
the baud rate, which can be changed via the DIP switches or
2400.N.8.1
software the available baud rates are: 1200, 2400, 4800 and
001
9600. "N.8.1" represents the Check bit,
bit.
300
 DOME ID: This is the address number of the dome. The
range is 000-255.
 MODULE: Displays the brand and model of the installed
camera module.
 VERSION: Displays the current operating system.
 <COMM SET>
 DEVICE ID: Used to distinguish this dome from the ID of
other domes.
 CHECK ID: Enter the device ID above into this field to
enable address changes for just this camera.
 TARGET ID: Enter the new address you wish to assign to
this camera. It will be effective immediately after it is changed.
means the IR output power.