––– STEP 5 –––
INSTALLING AND CONNECTING
OTHER DEVICES
As well as the gearmotor with control unit (ALTO100C) the "ALTO" sys-
tem also comprises other optional devices and accessories which can be
installed at any time on the automation. The devices required to set up a
standard automation are described here in Step 5; the others (back-up
battery PR200 and SOLEKIT photovoltaic power supply) are described in
the chapter "Further details".
5.1 - CONNECTING THE GEARMOTOR ALTO100M
01. Remove the lower cover of the gearmotor without control unit, as
shown in
;
02. (for the next phases, refer to
4 screws of the ducting support and remove (Caution! - take care to
conserve the 2 spacers).
03. Loosen the cable clamp and pass the connection cable under-
neath; connect the 3 electric wires to the terminal board taking care
to observe the symbols on the label; then tighten down the cable
clamp screws.
Adjusting the gearmotor feet. Before proceeding, adjust the height
of the 2 feet at the rear of the gearmotor. These should touch the sur-
face of the post to increase stability of the gearmotor. These should
touch the surface of the post to increase stability of the gearmotor.
Then use a hex wrench inside the gearmotor, to make adjustments
as shown in phase 7 of
more than necessary: they just need to touch the surface.
05.
5.2 - INSTALLING AND CONNECTING THE FLASHING
LIGHT FL200
• The
• For connection to the Flash terminal, no polarity needs to be observed;
instead for connection of the shielded aerial cable, it is necessary to con-
nect the cable and sheath as shown in Fig. 25(06) and Fig. 26.
must be positioned near the door in a clearly visible position. It can be
For the installation procedure see Fig. 25.
5.3 - INSTALLING AND CONNECTING THE PAIR OF PHO-
TOCELLS PH200
Caution: disconnect the power supply to the system before performing
any installation operations.
them as close as possible to the door (maximum distance = 15 cm)
• a tube for passing the cables must be present in the fastening
01. Remove the front glass (Phase 01 - Fig.
02. Remove the upper casing then the internal casing of the photocell
(Phase 02 - Fig.
)
03. Perforate the lower casing in the point where the cables should pass
(Phase 03 - Fig.
)
- Position the lower casing in the point where the tube for the pas-
sage of the cables arrives and mark the perforation points (Phase
)
- Use a percussion drill to drill the wall with a 5 mm bit. Insert the 5
mm wall plugs (
- Pass the electrical cables through the relevant holes and fasten the
lower casing with the screws (
05. - Connect the electrical cable to the terminals of the TX and RX,
which must be connected in parallel to each other then connected
to the terminal on the control unit (Fig. 26). It is not necessary to
observe any polarity.
- Put back in place, in the following order, the inner casing followed
by the upper casing to be fastened with the two screws then, lastly,
insert the cover and exert slight pressure to close it (Phase 05 -
Fig.
).
15 – English
) Use a screwdriver to loosen the
. Caution! – Never tighten the feet
)
)
)
22
NALS
01. Remove the control unit from its seat with reference to the instruc-
tions in paragraph A.1 (chapter "Further details").
02. Adjusting the gearmotor feet. Before proceeding, adjust the height
of the 2 feet at the rear of the gearmotor. These should touch the sur-
face of the post to increase stability of the gearmotor. These should
touch the surface of the post to increase stability of the gearmotor.
Then use a hex wrench inside the gearmotor, to make adjustments
as shown in phase 7 of
more than necessary: they just need to touch the surface.
03. Drill the rubber section of the hose connectors required and route the
connection cables through the holes.
Re-connect the connector of the motor to the control unit (caution:
take care to observe polarity: this can only be inserted in one direc-
tion) and insert the control unit in its seat.
05.
Caution! – Seal off any gaps to prevent the ingress of insects to the
gearmotor.
06. Lastly strip the cables and connect each to the dedicated terminal,
with reference to
and the following warnings.
• It is recommended to remove the terminals from the control unit, to
• Always connect the cable of the antenna and cable from the motor
without control unit in strict observance of the polarity indicated in
26. All other connections can be made without the need to observe
polarity.
• All devices compatible with ECSBus technology must be connected
to the terminal "BUS" of the control unit (for further information on the
technology, read paragraph 3.3.3).
1