GENERAL SAFETY WARNINGS AND PRECAUTIONS (Instructions translated from Italian)
––– STEP 1 –––
CAUTION - Important safety instructions. Observe all the instruc-
tions as improper installation may cause serious damage
CAUTION - Important safety instructions. It is important to com-
ply with these instructions to ensure personal safety. Store these
instructions
• Before commencing the installation, check the "Product technical
specifications", in particular whether this product is suitable for au-
tomating your guided part. Should it be unsuitable, DO NOT proceed
with the installation
• The product cannot be used before it has been commissioned as
specified in the "Testing and commissioning" chapter
CAUTION - According to the most recent European legislation, the
implementation of an automation system must comply with the
harmonised standards set forth in the Machinery Directive in force,
which allow for declaring the presumed conformity of the auto-
mation. On account of this, all operations regarding connection
to the mains electricity, as well as product testing, commission-
ing and maintenance, must be performed exclusively by a qualified
and skilled technician!
• Before proceeding with the product's installation, check that all materi-
als are in good working order and are suitable for the intended applica-
tions
• The product is not intended for use by persons (including children) with
reduced physical, sensory or mental capacities, nor by anyone lacking
sufficient experience or familiarity with the product
• Children must not play with the appliance
• Do not allow children to play with the control devices of the product.
Keep the remote controls out of reach of children
CAUTION - In order to avoid any danger from inadvertent resetting of the
thermal cut-off device, this appliance must not be powered through an ex-
ternal switching device, such as a timer, or connected to a supply that is
regularly powered or switched off by the circuit
• Provide a disconnection device (not supplied) in the plant's mains pow-
er supply, with a contact opening distance that ensures complete dis-
connection under the conditions envisaged by Overvoltage Category III
• Handle the product with care during installation, taking care to avoid
crushing, knocks, falls or contact with liquids of any kind. Keep the
product away from sources of heat and open flames. Failure to ob-
serve the above can damage the product and increase the risk of dan-
ger or malfunctions. If this should happen, stop installation immediately
and contact the Customer Service
• The manufacturer assumes no liability for damage to property, items or
persons resulting from non-compliance with the assembly instructions.
In such cases the warranty does not cover material defects
• The weighted sound pressure level of the emission A is lower than 70
dB(A)
• Cleaning and maintenance to be carried out by the user must not be
effected by unsupervised children
• Before intervening on the system (maintenance, cleaning), always dis-
connect the product from the mains power supply
• Check the system periodically, in particular all cables, springs and sup-
ports to detect possible imbalances, signs of wear or damage. Do not
use if repairs or adjustments are necessary, because a failure with the
installation or an incorrectly balanced automated system may lead to
injury
• The packaging materials of the product must be disposed of in compli-
ance with local regulations
• Keep persons away from the gate when it is moved through the control
elements
• When performing a manoeuvre, keep an eye on the automated mech-
anism and keep all bystanders at a safe distance until the movement
has been completed
• Do not operate the automation if anyone is working on it; disconnect
the power supply before permitting any work to be carried out
INSTALLATION PRECAUTIONS
• Prior to installing the drive motor, check that all mechanical compo-
nents are in good working order and properly balanced, and that the
automation moves correctly
• If the door being automated has a pedestrian door, the system must
include a control device inhibiting the operation of the motor when the
pedestrian door is open
• Make sure that the controls are kept at a safe distance from moving
parts, while allowing a good view of these.
1 – English
• Unless a selector is used, the controls should be installed at least 1.5
m from the ground and must not be accessible
• If the opening movement is controlled by a fire-prevention system,
make sure that any windows larger than 200 mm are closed by the
control elements
• Prevent and avoid any form of trapping between the moving and fixed
parts during manoeuvres
• Permanently affix the manual operation label next to the element ena-
bling the manoeuvre itself
• After installing the drive motor, make sure that the mechanism, protec-
tive system and all manual manoeuvres operate properly