Outdoor Unit; Rooftop Installations - Friedrich MR24DY3JMA Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Outdoor unit

1. If an awning is built over the unit to prevent di-
rect sunlight or rain exposure, make sure that
heat radiation from the condenser is not re-
stricted.
2. Ensure the unit is unobstructed, allow proper
space on all sides according to the arrows
and distance measurements in the figures.
3. Do not place animals and plants in the path of
the warm air.
4. Take the air conditioner weight into account
and select a place where noise and vibration
are minimum.
5. Select a place so that the warm air and sound
from the air conditioner does not disturb
neighbors.

Rooftop Installations:

If the outdoor unit is installed on a roof structure,
be sure to level the unit. Ensure the roof struc-
ture and anchoring method are adequate for the
unit location. Consult local codes regarding
rooftop mounting.
Installation of Indoor, Outdoor Unit
more than
23 21/32(600)
more than
11 13/16(300)
more than
27 9/16(700)
more than
11 13/16(300)
more than
23 21/32(600)
Unit: inch(mm)
Installation Manual 9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mr36tqy3jmaMr49dey3jm

Table des Matières