STEP 2 - FLUSHOMETER INSTALLATION:
(see Figure 4)
1. Assemble Vacuum Breaker components (B, C, D) into the Outlet Tube
(E).
2. Assemble the outlet tube with vacuum breaker onto the Flushometer
Body (A) and tighten Coupling Ring (F) into the flushometer body.
3. Slide the assembly into the Fixture Spud (G) until it bottoms out on the
lugs (G1) and measure distance (dd) between the center lines of the
Flushometer Tail (A1) and the Supply Stop (H).
4. Remove Outlet Tube (E) from the Flushometer Body (A) and cut the
measured distance (dd) off the bottom Outlet Tube (E).

If the Flushometer Tail (A1) is below the Supply Stop (H) fitting you
will have to order 22" Outlet Tube 060401A, then repeat 1-4.
5. Clean debris from the Outlet Tube (E) and re-assemble as noted above.
ÉTAPE 2 - INSTALLATION DE LA SOUPAPE DE
VIDANGE:
(voir Figure 4)
1. Assemblez les composants de reniflard (B, C, D) dans le tube de sortie
(E).
2. Assemblez le tuyau de sortie avec reniflard sur le corps de la soupape
de vidange (A) et serrez la bague d'accouplement (F) dans le corps de
la soupape de vidange.
3. Faites glisser l'ensemble dans le raccord du dispositif (G) jusqu'à ce
qu'elle bute les cosses (G1), et mesurez la distance (dd) entre les lignes
médianes de la queue de la soupape de vidange (A1) et la soupape
d'arrêt (H).
4. Enlevez le tube de sortie (E) du corps de la soupape de vidange (A) et
coupez une longueur équivalente à la distance mesurée (dd) du tube de
sortie inférieur (E).

Si la queue de la soupape de vidange (A1) est au-dessous de la
soupape d'arrêt (H), vous devez commander le tube de sortie de 22 po /
56 cm 060401A, puis répéter les étapes 1-4.
5. Nettoyez les débris dans le tube de sortie (E) et ré-assemblez tel
qu'indiqué ci-dessus.
STEP 3 - FLUSHOMETER INSTALLATION:
(see Figure 5)
1. Install the Flushometer and Outlet Tube assembly (A) into the Fixture
Spud (F) with the Fiber Washer (D) and Rubber Washer (E).
2. Tighten the Coupling Nut (C) onto the Fixture Spud (F).

DO NOT over tighten the Coupling Nut (C).
W
3. Place Filter (G) between the Supply Stop (H) and the Flushometer Tail
(A1), with conical screen facing into the water flow.
 DO NOT push filter in too far.
W
4. Install flushometer and filter onto the Supply Stop (H) and tighten
Retaining Ring (A2).

DO NOT over tighten the Retaining Ring (A2).
W
5. Open Supply Stop (H) and check for leaks.
ÉTAPE 3 - INSTALLATION DE LA SOUPAPE DE
VIDANGE:
(voir Figure 5)
1. Installez l'ensemble de la soupape de vidange et du tube de sortie
(A) dans le raccord de dispositif (F) avec la rondelle de fibres (D) et la
rondelle en caoutchouc (E).
2. Serrez l'écrou de couplage (C) sur le raccord du dispositif (F).

NE PAS plus serrer l'écrou de couplage (C).
W
3. Placez le filtre (G) entre la soupape d'arrêt (H) et la queue de la soupape
de vidange (A1), avec l'écran conique faisant face au flux d'eau.
 NE PAS trop enfoncer le filtre.
W
4. Installez la soupape de vidange sur la soupape d'arrêt (H) et serrez
l'anneau de retenue (A2).

NE PAS excessivement serrer l'anneau de retenue (A2).
W
5. Ouvrez la soupape d'arrêt (H) et vérifiez l'étanchéité.
Fig. 4
A
B
D
E
Fig. 5
A
D
F
Page - 5 of 19
213104 Rev. A
E
G1
C
F
G
A2
A1
G
B
C
E
A1
dd
H
dd
E