Troubleshooting for General Whirlpool Bath
PROBLEM
Pump/Motor does not start.
Pump/Motor operates but no fully
adjustable jets are functioning.
Pump/Motor operates but air is not
injected into water.
Pump/motor does not shutoff.
Water leakage from pump unions.
Pump/motor shuts off by itself or with
wall timer, before set time elapses.
Note: If unit is within the warranty period, contact Jacuzzi Whirlpool Bath Service Support at 1-800-288-4002 with
bath's serial number before work is started. The Serial Number is located on the Specification/Serial Number Plate.
See page 18.
Copyright © 2007 by Jacuzzi Whirlpool Bath
PROBABLE CAUSES
No power to pump/motor.
Pump/motor not plugged in.
Magic touch switch - air tube not con-
nected to switch or to air switch on
pump/motor.
Pump/motor faulty.
Jets are closed.
Suction cover may be clogged.
air entrapment.
air valves closed.
Magic touch switch - air tube not con-
nected to switch or to air switch on
pump/motor.
If a wall timer is used, the timer is
defective
over tightened, o-ring may be
pinched or improperly seated, under
tightened.
Motor thermal protection has deacti-
vated pump/motor due to overheat-
ing. (Supply voltage low.)
gFCI tripped.
Inadequate supply wiring.
1
REMEDY
Reset gFCI.
Insert plug fully into outlet.
Reconnect tube to Magic touch
switch or to air switch pump/motor.
Replace pump/motor assembly.
Open jets by rotate counterclockwise.
With motor turned off, remove safety
cover and remove any debris. Re-
place suction cover before operat-
ing.
Ensure that water level is at least 1"
2" (25 mm to 51 mm) above the high-
est jet.
open air control valves.
Reconnect tube to Magic touch
switch or to air switch pump/motor.
Replace timer.
Untighten unions check and reseat
o-ring. If o-ring has been pinched
out of shape, replace (refer to Service
Support number below). When tight-
ening union nuts, hand tighten only.
Let motor cool; thermal protection will
reset. Check for proper ventilation.
(Check supply voltage.)
Reset gFCI. If it continues to trip do
not use this unit. Disconnect the unit
and have the problem corrected by a
licensed electrician before using.
Consult a licensed electrician to cor-
rect wiring to unit.
U961000K 06/07