INSTALLATION INSTRUCTIONS (CONTINUED)

Electrical Information

either flat blade terminal. The wire with insulation having an outer surface that is green with or without yellow stripes
is the grounding wire.
DO NOT USE AN EXTENSION CORD, USE A LONGER AIR HOSE.
The 120 volt, 15 amp units can be operated on a 120 volt, 15 amp circuit under the following conditions:
1.
No other electrical appliances or lights are connected to the same branch circuit.
2.
Voltage is 120 Volts.
3.
Circuit is equipped with a 15 amp circuit breaker or a 15 amp slow blow fuse type T (For Canada use
Type D).
4.
The length of copper wire between the outlet and circuit breaker is not longer than 40 ft. of
14 AWG or 70 ft. of 12 AWG.
Grounding
This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the electric current. This product is equipped with a cord
having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet
that is properly installed and grounded in accordance with all local codes and ordinances. Do not use
grounding adapter.
ordinances by a qualified electrician.
This product comes from the factory ready for use on
a nominal 120 volt circuit and has a grounding plug
similar to the plug illustrated in Figure 8. If the listed
conditions cannot be met or if nuisance tripping
of the current protection device occurs, it may be
possible to operate the compressor from a 120 volt
20 amp circuit. See Figure 8.
Check motor data plate for 240 volt compatibility. A
240 volt unit must be operated on a 240 volt circuit.
The cord must only plug into a 240 volt grounded
outlet and may require a new cord and plug. See
Figure 9. This product may be modified to operate
at 240V. To do so, a 240V power cord needs to be
purchased and installed on the unit and wired into
the pressure switch just like the 120V cord. The
panel on the back of the motor needs to be opened
and the flag terminals need to be moved so that the
brown wire that is on terminal #1 is on terminal #7
and the white wire that is on terminal #3 needs to
be moved to terminal #1 (where the brown wire was
originally). See Figure 10.
Improperly grounded motors are shock hazards. Make sure all the equipment is properly
grounded.
Improper installation of the grounding plug is able to result in a risk of electric shock. When
repair or replacement of the cord or plug is required, do not connect the grounding wire to
Overheating, short circuiting and fire damage will result from inadequate wiring.
Disconnect, tag and lock out power source, then release all pressure from the system before
attempting to install, service, relocate or perform any maintenance.
Damage to the motor from improper electrical voltage or connection will void the warranty.
Improperly grounded electrical components are shock hazards. Make sure all the
components are properly grounded to prevent death or serious injury.
Improper use of grounding plug can result in a risk of electrical shock. Plug must be plugged
into an outlet that is properly installed and grounded in accordance with local codes and
10
Outlet -
120V/20A
Ground Pin
Figure 8
Grounded Outlet
Outlet - 240V
Ground Pin
Figure 9
Grounded Outlet
Outlet - 120V/15A