Operating Instructions and Parts Manual
Introduction
Pressure Switch - ON / OFF Switch
(
) - In the ON position ( ), the
compressor shuts off automatically
when tank pressure reaches the
maximum preset pressure. In the OFF
position (
), the compressor will not
operate. This switch should be in the
OFF position (
) when connecting or
disconnecting the power cord from the
electrical outlet.
Regulator - The regulator controls
the amount of air pressure at the
hose outlet. Turning regulator knob
clockwise (to the right) will increase air
pressure at the outlet. Turning knob
counterclockwise (to the left) will lower
air pressure to the outlet. Turning knob
fully counterclockwise will shut off flow
of air completely.
Handle - Designed to move the
compressor.
ASME Safety Valve - This valve
automatically releases air if the tank
pressure exceeds the preset maximum.
Exhaust Tube - This tube carries
compressed air from the pump to the
check valve. This tube becomes very hot
during use. To avoid the risk of severe
burns, never touch the exhaust tube.
Check Valve - A one-way valve
that allows air to enter the tank, but
prevents air in the tank from flowing
back into the compressor pump.
Regulator
Outlet
Pressure
Gauge
Air Outlet
Drain Valve
Figure 1
www.chpower.com
Air Outlet - A quick connect coupler
designed to work in combination with
a quick connect plug to quickly and
easily join the compressor to an air
hose.
Pressure Gauges - These gauges will
show air pressure in the compressor
tank and at the compressor outlet.
Outlet Pressure Gauge - Will show
air pressure at the outlet in pounds per
square inch (psi). Make sure this gauge
reads ZERO (by adjusting regulator
knob fully counterclockwise) before
changing air tools or disconnecting air
hose from outlet.
Tank Pressure Gauge - Will show air
pressure in tank while the compressor
is running, indicating compressor
is building pressure properly. This
gauge will show maximum pressure
of compressor when it shuts off
automatically at the pressure switch.
Drain Valve - This valve is located
underneath the tank. Use this valve to
drain moisture from the tank daily to
reduce the risk of corrosion.
Reduce tank pressure below 10 psi,
then drain moisture from tank daily to
avoid tank corrosion. Drain moisture
from tank by opening the drain valve
located underneath the tank.
Handle
ASME Safety Valve
Motor Specifications
and Electrical
Requirements
POWER SUPPLY AND MOTOR
SPECIFICATIONS
the risk of electrical
hazards, fire hazards
or damage to the tool,
use proper circuit protection. Your
tool is wired at the factory for
operation using the voltage shown.
Connect tool to a power line with
the appropriate voltage and a
15-amp branch circuit. Use a 15-
amp time delay type fuse or circuit
breaker. To reduce the risk of shock
or fire, if power cord is worn or
cut, or damaged in any way, have it
replaced immediately.
The A-C motor used on this compressor
is a capacitor start, capacitor run non-
reversible induction type, having the
following specifications. It is wired at
the factory for operation on 110V-120V
AC, 60 Hz service.
Drain liquid from
tank daily.
GENERAL ELECTRICAL CONNECTIONS
1. Use only identical replacement
Tank
Pressure
Gauge
2. Do not use in rain or where floor
the terminals of plug when
installing or removing the plug to
or from the outlet.
110-120 VOLT, 60HZ INFORMATION
The plug supplied on your compressor
may not fit into the outlet you are
planning to use. Your local electrical
code may require slightly different
power cord plug connections. If these
differences exist refer to and make the
proper adjustments per you local code
before your compressor is plugged in
ON / OFF
and turned on.
Switch
4
To
reduce
Motor Specifications
Voltage
Amperes
Hertz (Cycles)
Phase
RPM
To reduce the risk
of electrocution:
parts when servicing. Servicing
should be performed by a qualified
technician.
is wet. This tool is intended for
indoor residential use only.
Do not permit
fingers to touch
110-120
14
60
Single
3450