Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.
Install air filter. See Figure 5.

Lubrication

This unit contains no oil.
Before operating compressor, fill
to the center of the sight gauge (see Figure 7).
Using any other type of oil may
shorten pump life and damage
valves.
Recommended Oil (2 Options)
Single viscosity SAE 30 ISO100 nondetergent compressor
oil. Part number ST125303AV (0.5 qt) or ST126701AV (4
qt).
10W30 synthetic oil such as Mobil 1
Oil Capacity
Approximately 15.2 oz.
Remove oil fill plug on pump. Check oil level; some
models are shipped with oil in the pump. Add oil
if needed. Fill the pump with oil to the center of
the sight gauge using oil fill opening (see Figure 7).
Place oil fill plug back on pump.
through the breather cap opening as this may cause oil to
leak and spray out during operation.
Do not use regular automotive oil. Additives in
regular motor oil can cause valve deposits and
reduce pump life.
For maximum pump life, drain and replace oil after
the first 50 hours of run time and then follow the
regular maintenance schedule outlined later in the
manual.
This pump has an oil sight glass as shown in Figure 6.
Oil level can be monitored and maintained as shown
in Figure 7.
NOTE: Some residual oil may still be in the pump
from factory testing leaving a thin coat on the sight
gauge; however, there is not enough oil to operate
the unit.
Figure 5
Sight Glass
or CE0032 (1 qt).
®
Oil Drin Plug
Figure 6
Do NOT fill the pump
Figure 7
9
Air Filter
Oil Fill Area
Full
Low
Sight Glass

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Xc302100

Table des Matières