Observe the minimum water submersion when using level control devices. It is imperati-
ve to prevent trapped air in the hydraulics housing and the pipe system and remove any
trapped air using suitable ventilation systems. Protect the submersible pump from frost.
6.2.
Installation types
• Vertical stationary installation, immersed. If the submersible pump is not installed in a
well, it is necessary to install a cooling shroud.
• Horizontal stationary installation, immersed – only in conjunction with a cooling shroud!
The pressure output of the submersible pump must always be above the horizon-
tal axle!
Examples of installation with solar power supply (Fig. 2)
Fig. 2.: Installation with solar power supply
1
Actun OPTI-QS..
2
Solar panel
3
Connection cable (power supply)
4
Pressure pipe
60
5
Water tank
6
Float switch
QS Stop Module switchgear
7
(optional accessory)
INSTALLATION
WILO SE 02-2019 DIN A5