7
Quick-Start
Steam operation at temperatures up to approx. 65°C only:
Refer to chapter 1 Operating Modes.
1. Turn on the control according to chapter 5.1.
2. Using the knob 4 set the desired temperature at a range 5 of 40°- 65°C.
Note (with a pencil mark) the temperature most agreeable to you.
2. Set the desired steam output using the knob 7.
Note (with a pencil mark) the steam output most agreeable to you.
3. Briefly press time key A (less than 2 seconds)
• The heater starts.
• The steam generator starts to work.
• The signal lamp 1 is lit constantly.
The steam output is implemented by quickly turning on and off the steam generator. The time for turning the generator
on and off depends on the steam output selected.
• In display 3 the symbol for steam generator running will appear (see chapter 2).
4. Shut-off the operation of the steam generator by turning knob 7 to the "off" position. The cabin-drying programme
will start automatically (see Chapter 11). The following will appear in the display 3: dry.
Should operation of the sauna be desired after the steam generator, first turn the knob 4 from the area 5 in the sector
with the dark background, and then the knob 7, to the "off" position.
NOTE - In regard to drying we recommend observing the instructions provided by the manufacturer.
As a general rule, the drying programme should not be prematurely ended since this could cause damage to the cabin (e.g. the formation of mould and rotting).
8
Sauna operation
8.1 Setting the desired time
You can set the time, after which the stove is to start heating. You can set the time at a minimum of 15 minutes (display
00.15), or at a maximum of 23 hrs. and 45 minutes (display 23.45).
NOTE - Optional sauna door safety-monitor:
(refer to chapter 3):
1. Turn on the control according to chapter 5.1.
2. Press and hold time key A.
• The desired time is reset to zero and from thereon will count at 15 minute increments.
3. Release time key A.
• The display 3 indicates the desired time.
• The time set starts and the remaining time until the stove will start is indicated.
4. Set the desired temperature using the knob 4.
Note (with a pencil mark) the temperature most agreeable to you.
After the desired time set has elapsed the stove will be started. If the cabin temperature measured is less than the desired
temperature set, the stove will respond. The stove will heat.
If the cabin temperature measured is greater than the desired temperature set, the stove will not respond.
5. Turn off the control according to chapter 5.2.
8.2 Cancelling the selected time
1. Briefly press the time key A.
• The desired start-time will be cancelled.
WE DO IT FIRST.
Instructions for use for the user
Figure 6
Steam Operation
at selected time
P. 12/20