Thermal safety:
Stove sensor with overtemperature protector,
shutdown temperature 139°C.
Automatic shutdown after, at the maximum of 6 hours (depending on the factory setting).
Dual sensor system with temperature controls via stove and bench respectively.
Optional sauna door safety-monitor when the desired time has been set:
• Without heating operation:
-
The desired time set will be cancelled on opening of the sauna door.
• With heating operation at temperatures below 40°C:
-
The heater will be turned off.
- Restarting the control is necessary.
• With heating operation at temperatures above 40°C:
-
The heater will shut down, if the sauna door remains opened for more than 5 seconds.
- Heating continues on closing the sauna door.
Range of adjustment:
Sauna operation:
Steam operation:
Steam generator:
Fan:
00 - 100 % fan capacity
Selected start-time:
Min. of selected start-time:
Max.of selected start-time:
Duration of heating:
* If used in apartment buildings, hotels, or similar buildings, the operational timeframe has to be limited to 12 hours.
WE DO IT FIRST.
Instructions for installation and use
40-125 degrees Celsius
above the stove.
40-65 degrees Celsius
at the bench.
00 - 100 % steam output
in 15 minute increments
15 minutes
23 hours 45 min.
Will be switched off automatically after 6 hours *.