Optional Door Switch; Tests - Sentiotec A3 Instructions D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4

Optional door switch

Mount the optional door switch according to the assembling instructions attached to the door switch, or in accordance
with the specifications of the cabin manufacturer.
5

Tests

Tests have to be conducted by an authorised electrical engineer.
WARNING - Danger of Electric Shock:
The following tests have to be conducted with supply voltage turned on.
1. Test contact to protective-conductor terminal.
2. Test the safety shutdown of the stove sensor / fuse with line:
- The lines have to be disconnected at the stove sensor to include the stove sensor lines in the test.
- When disconnecting the white or red stove sensor lead and when the white lead shorts out, the heating system has
to shut down by itself (red signal lamp flashes).
3. Test the phase interconnection for the sauna operation L1, L2, L3 to U,V,W.
4. Test the phase interconnection for the steam generator's operation L1, L2, L3 to U
WE DO IT FIRST.
Instructions for use for the user
, V, W.
1
P. 6/20

Publicité

Table des Matières
loading

Table des Matières