3
Optional sauna door
To offer protection from fire hazards, the sauna door will be monitored after the desired start-time has been set (time
until the stove turns on).
To prevent somebody from entering the cabin after the desired start-time has been set, and perhaps place an object on
top of the stove, the control has been equipped with a safety shutdown, which will respond according to the operational
status:
3.1 Operational status - stove does not heat
The desired start-up time has been set. Heater is not running yet. The sauna door is opened:
• You will hear a repeated beeping sound,
• the display 3 will indicate the message "door",
• the desired start-time will be cancelled.
After closing the sauna door, you will have to re-enter the desired start-time.
3
Optional sauna door
3.2 Operational status - stove is heating
The desired start-up time has elapsed. The heater is running. The sauna door is opened:
1. The temperature is below 40°C:
• You will hear a repeated beeping sound,
• The display 3 will indicate the message "door".
After closing the sauna door, you will have to re-enter the desired start-time or you will have to restart the control .
2. The temperature is above 40°C:
If you quickly open the sauna door (for less than 5 seconds) no message will be indicated. If the sauna door is opened
for longer than 5 seconds:
• you will hear a repeated beeping sound,
• the signal lamp 2 will flash,
• the heater will be turned off,
• the display 3 will indicate the message "door",
After closing the sauna door, the heater will be turned on again.
• The beeping stops,
• the displayed message "door" disappears.