MPPES
6
Operation
If the same output pressure is still evident despite a modified setpoint value specification:
Note
• Look for defective cables.
In the event of fractured setpoint cables (only MPPES-...-420B) or power supply
cables, the output pressure goes back to 0 bar.
When using the MPPES-...-10-...:
Warning
• Make sure the solenoid head is secured against direct contact.
The temperature of the magnet can rise in continuous operation to over +70 °C.
When the MPPES-1/8-10-... is used in an ambient temperature greater than 40 °C and an output pres-
sure greater than 8 bar (T > 40 °C and p
Note
• Make sure that the MPPES-1/8-10-... for cooling the magnets is operated only with
forced convection of the ambient atmosphere.
The magnets of the types MPPES-1/8-6-... and MPPES-1/8-2-... require no addition-
al cooling.
7
Disassembly and repair
On disassembly:
Note
• Switch off the following power:
–
–
8
Maintenance and care
• Clean the MPPES-... with soap suds only, max. +60 °C.
Festo – MPPES – 1304d English
> 8 bar):
2
compressed air
voltage supply
21