Desired Output % adjustment knob
This setting is used to control the amount of chlorine the Aqua Trol generates. Raise this setting to
increase chlorine level and lower it to decrease chlorine level.

Indicator LED's

POWER When illuminated, the Aqua Trol has input power.
GENERATING This LED is on steady during normal operation. When flashing, the pool water is too
hot or cold to operate.
SUPER CHLORINATE Illuminates during Super Chlorination. See description above.
NO FLOW When illuminated, the flow switch has detected no flow and the Aqua Trol has stopped
generating chlorine. A flashing LED indicates a 15/60 second time delay period.
CHECK SALT When flashing, the salt level is below 2700 ppm in Normal Salt Mode or below 1200
ppm in Low Salt Mode. Aqua Trol is generating at low efficiency. When illuminated steady, the salt
level is too low for operation and Aqua Trol has shut down. Before adding large quantities of salt, it
is advisable to have your salt level professionally checked.
HIGH SALT When illuminated, the salt level is too high and Aqua Trol has shut down.
INSPECT CELL A flashing indicator signifies that either the cell efficiency is reduced or that it is
time for regularly scheduled cell inspection. In either case, inspect the cell and clean if necessary.
Pressing the "diagnostic" button next to the display for 3 seconds will stop the flashing LED. When il-
luminated steady, cell efficiency is greatly reduced and the Aqua Trol has stopped producing chlorine.
Inspect, clean or replace if necessary.
Diagnostic Displays
Sequential pushes of the small "diagnostic" button next to the LCD display will cause the Aqua Trol
to display the following information:
1.
Pool temperature (xx degrees Fahrenheit or Celsius)
2.
Cell voltage (typically xx.x volts when chlorine is being generated, otherwise 30-35V)
3.
Cell current (typically x.xx amps when chlorine is being generated, otherwise 0 amps)
4.
Desired Output % ("0P" -- "100P" depending on knob position )
5.
Instant salinity ( -xxxx ppm or -x.xx grams/Liter)
6.
Product name sent to the display ("AL-6" signifies "Aqua Trol" (STD), ("AL-7" signifies "Aqua
Trol Return-Jet")
7.
Software revision level (r1.xx)
8.
Salt Mode (nSlt = Normal Salt Mode, lSlt=Low Salt Mode)
On the 9th push of the button the display will revert back to the default salt display. Also, if the button
is not pushed for 30 seconds, the display will revert back to the standard salt display.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
9