Supplementary to fig. 9 and fig. b
A
NOTICE!
Use a permanently elastic adhesive.
Observe the adhesive manufacturer's instructions.
If you are using Sikaflex 252 or Sikaflex 221, treat the bonding surfaces
of the service door with Sika activator 205 and Sika primer 215.
Supplementary to fig. a
➤ Insert the linkage through the outer guide tabs on the door frame.
➤ Use the fastening clips to attach the linkage into the boreholes on the closing
bars.
Supplementary to fig. d
A
NOTICE!
Do not lock the mounted door until the adhesive is fully cured.
➤ Close the door without locking it.
➤ Check whether there is a uniform gap between the door and the outer frame.
If necessary, align the outer frame.
Supplementary to fig. e
➤ Cut about 10 mm out of the bottom of the rubber seal.
This slot is used for air balancing in the seal.