GYS SMART HUB MODUL Manuel D'utilisation page 13

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Operating manual
Uncap the GYSFLASH CNT.
Unplug your GYSFLASH at least 10 minutes before disassembly. This operation should only be carried
1
out by a qualified person
Locate the micro-switches that allow you to change the Mas-
2
ter/Slave positi on of t he charger .
When it leaves the factory, the GYSFLASH is always in the
Master position.
Depending on the desired configuration, set the position of the
GYSFLASH as shown below:
Each GYSFLASH in parallel must be in a different position.
It's not possible to have tw o Mast er products or t wo of Sla ve 1 for example.
Recap the GYSFLASH CNT.
3
Switch on the Master Charger and perform the following operation to activate the "Multi-Charger" mode:
4
- Press the MODE button for 3 seconds to access the "Config-
uration" Menu
- Use the arrow keys to navigate to "Multi-Charge r mode".
- Press Select to enter the mode.
- Press Select again to activate the mode and use the arrows
to select the configuration that suits your installation: « MAS-
TER + 1 SLAVE » — « MASTER + 2 SLAVE » — « MASTER
+ 3 SLAVE ».
Translation of the original
instructions
Master
Slave 1
Slave 2
Slave 3
SMART HUB MODULE
CONFIGURATION
Multi-charger Mode
Multi-Charger mode
OFF
Multi-Charger mode
MASTER + X SLAVE
13