Operation

Connect the unit to a suitable power source, note require-
ments on the ID plate. If an extension cord is to be used,
only waterproof cords are acceptable.
Th e DC 2800 H Asbestos is equipped with a fi lter indica-
tion lamp that indicates when the fi lter needs cleaning or
changing.
Th e fi lter is genereally cleaned once or twice daily during
normal continuous operation. Th e unit must be in operation
to perform fi lter cleaning. Loose the tube from the suction
pipe and press the plastic cage against the black stop head
on the exhaust channel so that maximum pressure is created
in the cyclone.
Open the port on the side o the unit three to six times. Th is
reverse pulse of air cleans the fi lter.
Th e plastic sack should be changed only after fi lter cleaning
is done and when the collected material level is about 5 cm
under the foot valve.

Service

With cleaning and maintenance on the machine, the power
cable should be disconnected from the supply.
Th e engine package, the fi lter pads (2 pieces, art no
432160) and air fi lter (1 piece, art no 432159) need to be
changed at least six times a year, and when cleaning the
machine. Th ese fi lters can be ordered in a kit, part no
432183.
Th e collection sack must be tied off when it is removed
from the unit. Th is is most easily done with the sacks own
tie strap. Be sure to put on a new strap before installing a
new collection sack. Follow the instructions below. Use only
original Dustcontrol spare parts.