3. Operating instruction

3.1 Instructions before use

a) Compare line voltage with indication given on the cable.
As standard the heaters are supplied connected for either 2 x 400 V
or 2 x 460 V.
The plug should be connected as follows:
- yellow/green wire
- brown
- blue
Only two of the three phases are used.
For the TIH 240 a 63 A fuse of the slow blow type should be used.
b) The heater must be placed in horizontal position and on a stable
support.
c) If the temperature mode is to be used, connect the temperature probe
with the heater.
d) Switch on the main switch by pulling up the handle on the side of the
heater. Press the ON/OFF key on the keyboard and the signal lamp
will light up, indicating that the heater is ready for operation.
e) Always use the biggest possible yoke to obtain shortest heating time.
Never operate the heater without yoke.
f) Make sure that the protection film is removed from the yoke and place
it with the laminated face downwards.
g) The probe should be attached to the inner ring of the bearing, or as
close to the yoke as possible.
h) Select the heating temperature or time and start the heater according
to the instructions for use of the keyboard (paragraph 3.2).
«БЕРГ АБ», (495) 727-22-72, promshop-biz@ya.ru, www.promshop