DUO
DUO
DUOX X X X X
DUO
DUO
DUO
DUO
DUOX X X X X
DUO
DUO
5. From a street panel, make a call to the first address in the range. The last address
should be greater than the first one. All leds should be off.
Notice:
- To configure the first and last addresses in the range to make the call from a push-button
panel, press the corresponding buttons for these addresses as indicated in steps 4 and
5. Remember that if the panel has a keypad, the call is made by entering the residence
number + the bell key.
Steps to DELETE the entered range.
1. Press the PRG button twice, the D led should light up.
2.
Simultaneously press the Sec/Single and Min/All buttons. All leds should be off. The
range entered has been deleted.
Third step: Configuration of the activation time.
To configure the activation time, follow point: 2.2 ACTIVATION TIME CONFIGURATION VIA
THE INTEGRATED BUTTONS (SEC/SINGLE - MIN/ALL)
3. TECHNICAL FEATURES
- Power supply: 18 Vdc (non-polarised, via the BUS INPUT or BUS OUTPUT).
- Consumption:
* On standby: 28 mA.
* Maximum: 64 mA (without power in the output and without the programmer connected).
- Operating temperature: [0, 40ºC].
- IP Address: 20.
- (+12V): Auxiliary voltage output 12Vdc (300 mA max).
- Dry contact relay:
- C: common.
- NC: normally Closed.
- NO: normally Open.
* Maximum current 3A.
* Maximum voltage 300VAC or 60VDC.
Page 16