DUO
DUO
DUOX X X X X
DUO
DUO
DUO
DUO
DUOX X X X X
DUO
DUO
5. From a street panel, make a call to the first address in the range. The last address
should be greater than the first one. All leds should be off.
Notice:
- To configure the first and last addresses in the range to make the call from a push-button
panel, press the corresponding buttons for these addresses as indicated in steps 4 and
5. Remember on a keypad panel, the call is made by entering the residence number +
the bell key.
Steps to DELETE the entered range.
1. Press the PRG button twice, the D led should light up.
2.
Simultaneously press the Sec/Single and Min/All buttons. All leds should be off. The
range entered has been deleted.
Third step: Configuration of the activation time.
To configure the activation time, follow point: 2.2 ACTIVATION TIME CONFIGURATION VIA
THE INTEGRATED BUTTONS (SEC/SINGLE - MIN/ALL)
2.3.2.2 ACTIVATION OF THE RELAY UPON RECEIVING A CALL TO RESIDENCE COMMAND
FROM A STREET PANEL.
Function description.
You can configure the relay to activate upon receiving a call to residence command from
a panel.
The panel, upon making a call, sends a call to residence command to the residence's
terminal (or terminals). The relay, if configured this way, can activate upon receiving the
call residence command. The residence terminals can receive the call to residence
command from a specific panel or from all panels in the installation, understanding that
this command is sent individually to each terminal.
- The call to residence command, relative to the residence terminals receiving them can
be configured as:
* All installed terminals (ALL).
* Terminals from a list (maximum 100 terminals).
* Terminals included within a defined range (consecutive).
- The call to residence command, relative to the panels sending them can be configured
as:
* All panels (they individually send each command, not all in the group).
For example: In the installation the panels are P1, P2, P3, P4 and P5. The residence
terminal can receive a call from Panel P1 or Panel P2 or Panel P3 or Panel P4 or
Panel P5. Upon configuring the call to residence command in All panels, the relay
is activated when the call to residence command is sent from any panel.
* Only one panel.
For example: In the installation the panels are P1, P2, P3, P4 and P5. The residence
terminal can receive a call from Panel P1 or Panel P2 or Panel P3 or Panel P4 or
Panel P5. Upon configuring the call to residence command in a single panel, for
example, Panel P4, only when Panel P4 sends the call to residence command is
the relay activated.
Page 13