6. Operating Mode:
- TX: The mode where the relay sends commands to other devices depending on the
configured command (in this mode, the relay does not activate the output).
- RX: The mode where the relay activates the output if the configured command is
received by the bus and coincides with the other configured parameters.
7. PRG: Programming Access button.
8. Min all / sec single: Buttons for Functions and Activation Times
- For Functions: In combination with the PRG button (programming input), they are
pressed to program the relay's different possible functions.
- For activation times.
* Timed: This allows you to configure the activation time between 1 and 120 seconds
in the seconds range and between 1 and 120 minutes in the minute rage.
* Bi-stable: by activating the SET terminal it remains permanently activated until
deactivated by the RESET terminal.
9. C, D, T: LED diodes that give information when programming, relative to the status: off,
on, fast flash...etc.
10. Telephone Connector: For the DUOX Programmer connection.

1.1 AVAILABLE FUNCTIONS/ CONFIGURATIONS

The functions available on the relay are summarised below. This manual describes the
most common uses.
In the DUOX Relay Advanced Manual cod. 97822 at www.fermax.com you can find all of
them, including configuration from a Duox Programmer.
Available functions in TX Mode:
- Lock-release function after receiving a call.
- Lock-release function to a configured panel.
- Guard-unit call function.
- F1 relay activation or deactivation function.
- F2 relay activation or deactivation function.
- Remote relay activation or deactivation function.
- Doormatic function.
Available functions in RX Mode:
- Activating the relay upon receiving a lock-release command.
- Activation upon receiving a guard-unit call command.
- Activation upon receiving a call to residence command from a panel.
- Activation upon receiving an Auto-on command.
- Activation upon receiving an Activate F1 relay command.
- Activation upon receiving an Activate F2 relay command.
- Activation upon receiving an Activate/Deactivate relay command.
- Activation of the relay for an indefinite time.
Other configurations: