Readiness for use requires that the ground sleeve has already been installed properly. The screws for
fastening the ground sleeve are not included in the scope of supply. Ensure that the ground sleeve is
Insert the cantilever arm into the IKAR sleeve.
The lower, round part of the lower arm of the cantilever arm has eight holes for the locking pin, which
enables locking in 45° increments. Swivelling in a range of 360° is possible without locking.
Release the safety bolt (
Then fold the cantilever arm upwards (
The cantilever arm is now ready for basic use.
Reverse the steps for disassembly.
A
ENGLISH
Preparing readiness for use
IKAR cantilever arm
correctly fastened and aligned.
) by pressing with the thumb and pull out.
A
) and lock in with the safety bolt (
B
Before the system is activated, section 10 of the Ordinance on Indus-
requires a qualified person to check the installation. The
IKAR cantilever arm can then be put into operation.
The operating instructions of the IKAR cantilever arm as well as
further IKAR devices should always be observed.
Caution:
B
Please note:
trial Safety and Health
25
).
C
C