Specifications
Voltage: ................................................................................................................. 100-240V∼ 50/60Hz
Fuse: ............................................................................................................................. 5A - 250V
Power consumption: ....................................................................................................................................... 150W
Light source: ........................................................................... 7pcs of 12W 4 in 1 OSRAM LED, RGBW
Pan: ...................................................................................................................................... 540°
Tilt: ....................................................................................................................................... 270°
Function: .......................................... Sound control, Auto-run, Master/Slave, DMX512, Strobe
Max. Ta ................................................................................................................................. 40°C
Channel: ............................................................................................. 6, 13 or 37 DMX channels
Data input.................................................................................... Locking 3-pin XLR male socket
Data output ............................................................................ Locking 3-pin DMX female socket
Data pin configuration ................................................................. Pin1 shield, pin 2 (-), pin 3 (+)
Dimensions .................................................................................................. 304 x 267 x 167 mm
N.W: .................................................................................................................................... 6.2kg
Disconnect the power cord before replacing a fuse and always replace with the same type fuse.
Fuse Replacement
With a flat head screwdriver wedge the fuse holder out of its housing.
Remove the damaged fuse from its holder and replace with exactly the same type of fuse.
Insert the fuse holder back in its place and reconnect power.
The fuse is located inside this compartment. Remove using a flat head screwdriver.

Fixture Linking

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run
synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of
channels required by all fixtures on a serial data link determines the number of fixtures that the data link can
support.
Important: Fixtures on a serial/data link must be daisy chained in one single line. Maximum recommended serial
data link distance: 500 meters (1640 ft.) Maximum recommended number of fixtures on a serial data link: 32 fixtures
Data Cabling
To link fixtures together you must use data cables. If you choose to create your own cable, please use data-grade
cables that can carry a high quality signal and are less prone to electromagnetic interference.

CABLE CONNECTORS

Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
DMX connector configuration
Termination reduces signal errors. To avoid signal transmission problems and interference, it is always advisable to
connect a DMX signal terminator.
©Copyright LOTRONIC 2015
COMMON
DMX +
INPUT
DMX-
LEDWASH712
Resistance 120 ohm
1/ 4w between pin 2
(DMX-) and pin 3
(DMX+) of the last
fixture.