Audible Continuity Test - Semi-Conductor Test; General Characteristics; Dimensions And Weight; Power Supply - Metrix MX 1 Notice De Fonctionnement

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
English
NB : In Ω x 1 : "buzzer" threshold ≤ 250Ω, control of diode on or blocked
Audible continuity
test - semi-conductor
(
test
On the ohmmeter, calibre Ω x 1, if voltage of VAC > 5V (rms) is applied,
the « buzzer » issues a modulated sound until the error has been
corrected.

General characteristics

• 97 x 155 x 43 mm
Dimensions and
• 420 g
weight
• 1.5V battery (R6 saline or LR6 alkaline)

Power supply

• Battery life:
about 250 hours for the ohmmeter with an alkaline battery
4000 5-second measurements for R < 50Ω (with beep)
• Temperature
Maximum climatic
• Relative humidity
conditions
• Altitude
Electrical safety (EN 61010-1)
Compliance with
international
CEI 1010-1 EN61010 NF-C 42020 VDE 0411
standards
Double insulation :
Pollution level : 2
Installation category : III according to CEI 664
Allocated voltage : 600V
Emission (EN 61326-1)
Electromagnetic
Immunity (EN 61326-1)
compatibility
Maximum influence in the presence of conducted radio frequencies: 3 times
the accuracy class if the length of the measured circuit is > 3 m.
Watertightness (EN 60529/A1)
Mechanical
Protection index: IP65
protection
Multimeter MX1
, anode in "COM" for on). Do not carry out live measurements.
use -10°C to +50°C ; storage -30°C to +70°C
use ≤ 80% HR
use < 2000m
19

Publicité

Table des Matières
loading

Table des Matières