3.3

Resistance measurement

Never test a resistance on a live circuit.
• Connect the leads - preferably twisted - to the multimeter (COM
and Ω terminals) and to the circuit or the component to be tested.
• Position the selector switch on the ohmmeter function " Ω ".
• Automatic range selection : read the measured value.
• Memorise the value, if necessary, by pressing the " MEM " key.
• Overload : the beep sounds and " OL. " blinks.
400 Ω
Range
4 kΩ
0.1 Ω
1 Ω
Resolution
Accuracy
± 0.5 % R ± 4 D
Voltage on
open circuit
Measurement
current
Protection
3.4

Continuity sound test

• Connect the leads to the multimeter (COM and Ω terminals) and to
the circuit or the component to be tested.
• Position the selector switch on the continuity sound function "
• Audible beep when R < 40 Ω.
• Protection : 600 Vrms.
• Output voltage in open circuit < 2 V
• Overload : " OL. " or every segments of the bargraph are displayed.
3.5

Diode test

Never test a diode on a live circuit.
With this function, it is not only possible to test classic diodes, but
also LED's or any other semiconductor in which the junction
corresponds to a direct voltage less than 3 V.
• Connect the leads to the multimeter (COM and
to the circuit or component to be tested.
• Position the selector switch on the "
• Max. output voltage : 4 V in open circuit
• Short-circuit current : 1 mA
• Overload : the beep sounds and " OL. " blinks.
• Memorise, if necessary, by pressing the " MEM " key.
• Protection : 600 Vrms.
3.6

Frequency measurement

• Connect the leads to the multimeter (COM and V terminals) and to
the circuit the frequency of which is to be tested.
• Position the selector switch on the " Hz " function.
• Automatic range selection : read the measured value.
• Memorise, if necessary, by pressing the " MEM " key.
• Overload : " OL. " blinks.
• ... /...
22
40 kΩ
400 kΩ
4 MΩ
40 MΩ
10 Ω
100 Ω
1 kΩ
10 kΩ
± 1 % R
± 2 % R
± 5 D
< 2 V
0.4 mA
600 Vrms
terminals) and
" function.
Portable 4000 count digital multimeter
± 5 D
".

Publicité

loading