Meaning Of The Leds On The Pp 45 Rc; Radio Components Which Can Be Taught In; Teaching-In Tips; Ds 45 Rc Radio Switch - Maico PP 45 O Notice D'utilisation

Système de ventilation pushpull
Masquer les pouces Voir aussi pour PP 45 O:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7.1 Meaning of the LEDs [17] on the
PP 45 RC
LED
Meaning
Or-
LED flashes x times when the heat
ange
recovery (WRG) operating mode is
selected (x = selected ventilation
level). When demand-driven oper-
ation is selected, the LED lights up
for 5 seconds.
Blue
LED flashes x times when the
cross-ventilation operating mode is
selected (x = selected ventilation
level). When demand-driven oper-
ation is selected, the LED lights up
for 5 seconds.
Red
Filter change display and fault indi-
cator light  Chapters 10.2 and 11.
7.2 Radio components which can be
taught in
PP 45 radio components must support
i
the EEP protocol. Radio components
with the same EEP no. can be
combined with the PP 45 system.
Type

DS 45 RC radio switch,

4-channel wall transmitter
Humidity/temperature sensor
CO
/temperature sensor
2
VOC/temperature sensor*
PP 45 Act: 1-channel re-
cessed-mounted switch
* No EnOcean VOC sensor currently available.
7 Radio-controlled operation (EnOcean) | UK

7.3 Teaching-in tips

● Radio components are taught in directly on
the master PP 45 RC (LEARN key).
● Only one slave unit can be assigned to
each master ventilation unit.
● Correction operation of a unit pair is moni-
tored by the master unit.
● Teach-in mode is deactivated each time a
radio component is saved, meaning that it
has to be called up again for each further
component.
● If nothing is received within 120 seconds,
the teaching-in process is ended (the LED
on the ventilation unit switches off).
● Teach-in telegrams from non-supported
units are ignored.
7.4 DS 45 RC radio switch
The DS 45 RC ( Fig. A) is a double rocker
radio switch for operating PP 45 RC ventila-
tion units. The operating mode and ventilation
level is transferred to all taught-in PP 45 RC
master ventilation units.

7.5 EnOcean extension module PP 45 EO

EEP
This module can be used to add radio
F6-02-01
components to an
Once radio mode has been activated by your
A5-04-01
specialist installer, radio-controlled RC units
can be integrated into the wired system.
A5-09-08
A5-09-05
D2-01-01
RLS 45 K
comfort control.
31

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pp 45 kPp 45 rcRls 45 oRls 45 kDs 45 rc0095.0241

Table des Matières