Error codes (continued)
No. Error
10
Contact with the add-on board
has been lost.
11
There is a fault in the emptying
of water from the steam tank.
Switch off the power and per-
form service.
12
Steam tank level electrodes are
not working, mid failure.
13
Humidity sensor is not wor-
king.
14
Temperature sensor not wor-
king.
15
Contact lost with the relay
board.
16
Temperature cut-out activated
and must be reset manually.
17
Room overheated.
18
Too many secondary units
connected.
19
Door has been open for longer
than the permitted time. Cur-
rent session ends.
20
Door switch has been open for
longer than 60 seconds since
the previous session.
Comments/Troubleshooting
Check the RJ45 cable between the circuit board and the
add-on board. Is the green LED lit on the add-on board?
Try to start ON operation again to try and restore the
contact. Try replacing the RJ45 cable or add-on board.
Check whether the water tank drain is blocked. Is the
draining valve intact? This error may also be caused by
High detecting water when Mid does not.
Check the cable connections between the circuit board
and the mid electrode. Check if the mid electrode pin is
coated with surface coating; if so, clean the electrode pin.
Try restarting the system or replacing the temperature/
humidity sensor that is connected to the RS485 input.
Try restarting the system or replacing the temperature/
humidity sensor that is connected to the RS485 input.
Appears when the primary unit has lost contact with
the connected secondary unit. The system will fix itself.
Check synchronisation cables and voltage to secondary
units. After the error is rectified, the system reboots to
include all secondary units in system operation.
Combined temperature cut-out/temperature sensor in
sauna is reset via a push button on the sensor.
The room temperature exceeds the maximum permitted
value.
Only two secondary units may be used.
Close the door and start a new session. If the error recurs
immediately, check the door switch. If the error is repe-
ated despite the door being closed, check the function/
installation of the door switch. You can see whether the
door switch is connected under Configure/Status.
Check that nothing is lying on the sauna device, close
the door and start session. If the error is repeated despite
the door being closed, check the function/installation of
the door switch. You can see whether the door switch is
connected under Configure/Status.