Page 12
Pod
Figure 3.

installation Requirements

3.3

install the Power Pack, Cell, and Pod

WARning
If you are installing a Zodiac AquaPure Ei Series
APURE35PLGC to Goldline
disconnect the power to the Goldline controller.
Zodiac recommends that any procedure requiring
potential contact with live electrical wiring and/or parts
other than cords and plugs connected to electrical
outlets be completed by a contractor who is licensed and
qualified in pool equipment as described on the front
cover of this manual. Failure to follow warning notices
and instructions may result in property damage, serious
injury, or death.
* The Goldline brand is property of Hayward Industries, Inc. and/or its subsidiaries or affiliates. All other trademarks used herein are property of their respective owners
Zodiac
AquaPure
®
Power Pack
4.6 m (15 ft.) MAX
Cell
adaptor, it is necessary to
®
|
Ei Series APURE35PLGC
Installation and Operation Manual
®
The Canadian Electrical Code (CEC
pool equipment be bonded to each other. Make sure
to check your local codes to determine if the CEC,
and/or other local installation codes are enforced
by the Authority Having Jurisdiction (AHJ). A solid
copper bonding wire 13.3 mm
with this product for bonding the power pack to a
permanent bonding connection. Refer to your locally
enforced codes for the acceptable bonding wire
gauge.
To avoid property damage, serious injury or death,
NEVER use the chassis backplate of the power pack
to ground any other equipment.
1.
Ensure correct placement of the cell and
the power pack will meet all the installation
requirements outlined in Section 3.2.
2.
Screw the power pack bracket into position on a
wall surface where it will mount securely, while
ensuring it is no more than 4.6 m (15 ft.) from
the cell (see Figure 4).
3.
Position the power pack in place by aligning the
bracket with the corresponding thru-holes (see
Figure 4).
Figure 4.

Attaching the Power Pack

4.
Unscrew the locking ring from the cell and the
pod in order to extract them from the lower
clamp (see Figure 5).
5.
Press the two (2) push-buttons on either side
of the upper clamp to separate the upper clamp
from the lower clamp (see Figure 5).
WARning
) requires that
®
(6 AWG) is included
2