section 5. Operating instructions
WARning
To avoid property damage, serious injury or death, do
not operate the electrolytic cell without water circulation.
A buildup of flammable gasses which can result in FIRE
OR EXPLOSION.
5.1
Control Panel
Indicates level of chlorine output
production. Each light represents a
20% increment of output production.
Indicates there
is not enough
flow through
the cell
Flow
On/Off
Figure 26. Control Panel on the Power Pack
5.2
Turning Power Pack On/Off (Manually)
To turn the Zodiac AquaPure Ei Series APURE35PLGC
chlorine generating device on or off press the
button.
nOTE The power pack will only turn on and the cell will only
produce chlorine when water flow is detected by the
flow switch.
5.3
setting the Chlorine Output level
When setting the chlorine output level you must consider
the size of the pool, the amount of use the pool will be
receiving and how hot the weather is. All these factors
weigh greatly on the level of output needed. To adjust the
output level, follow these steps:
1.
Turn the power pack on by pressing the
button.
|
Ei Series APURE35PLGC
®
Check
salt
level
indicator
Salt
Output
TM
Installation and Operation Manual
2.
Press the
output level. The minimum setting is 20% (one
amber light). The output can be adjusted in
increments of 20% up to 100%. If the OUTPUT
button is pressed beyond 100%, the output level
setting will drop back to 20%.
Output setting
20% - one (1) light
40% - two (2) lights
60% - three (3) lights
80% - four (4) lights
100% - five (5) lights
5.4
Connection to an Aqualink
Control system
The Zodiac AquaPure Ei Series APURE35PLGC
chlorine generating device can be connected to an
AquaLink RS or PDA Control System (see Section 3.7).
For detailed instructions for the AquaLink RS or PDA
Control System, see the respective manuals.
5.5
Polarity Reversal
The Zodiac AquaPure Ei Series APURE35PLGC
chlorine generating device is a reversable polarity cell
which means that for every five (5) hours of operation
the cell will switch its polarity to help prevent any build
up of calcium on the cell plates. This is sometimes
referred to as the automated cell cleaning feature.
During the transition between changing its polarity there
is a five (5) minute wait time when the cell will not
produce any chlorine. Once it has changed polarity it
will continue to make chlorine.
nOTE 'CLEANING' will be displayed on the screen
during the five (5) minute 'WAIT' period. The
output level indicator will remain as set during
the cleaning period.
Page 23
English
button to reach the desired
Amount of time cell will run
Cell will run two (2) min.
every ten (10) min.
Cell will run four (4) min.
every ten (10) min.
Cell will run six (6) min.
every ten (10) min.
Cell will run eight (8) min.
every ten (10) min.
Cell will run non-stop.
®
Rs / PDA